Products

Solo High Efficiency

Solo High Efficiency
Solo High Efficiency
Pump unit to load one buffer tank
Compact fully assembled pump unit to supply the heat produced by a solar thermal installation with High Flow or Low Flow operating mode. Suitable to be used with 1 buffer storage tank.
It is supplied fully insulated and pre-wired, with pre-programmed controller and it allows a fast and easy mounting.

The unit consists of:

Primary solar circuit:
  • Flowmeter with flow regulation with filling and draining valves. Alternatively a digital flowmeter is also available.
  • Asynchronous circulating pump or synchronous pump in Class A.
  • 3-way return ball valve with check valve 10 mbar supplied with in-handle thermometer.
  • Security unit 6 bar with manometer ø50 mm 0-10 bar with 3/4” male connection to the expansion vessel.
  • Supply ball valve with check valve 10 mbar supplied with in-handle thermometer.
  • Air vent made of brass with automatic vent valve and isolating valve.
Heat exchanger:
  • Weld-braised plates heat exchanger made of stainless steel AISI 316 suitable for several powers.
Secondary circuit:
  • TÜV security valve 3 bar, 50 kW.
  • Asynchronous circulating pump or synchronous pump in Class A.
EPP insulation box (Measurements: 576x585x190).
A special back plate fixes the unit to the insulation box and it allows a quick fitting to the wall.


PN 10. Constant temperature on the solar circuit 120°C;
(short time: 160°C for 20 s).
Maximum temperature on the secondary circuit 110°C.
Available external connections:

  • 1” Male for solar circuit.
  • 3/4” Male pipe union for the secondary circuit.
FIELD OF UTILIZATION:
For power up to 35 kW. One buffer storage tank.
Kvs value: see the diagram here below.
A special ball valves kit, available upon request (to be ordered) completes the unit.


Typical curves of solar circuit

Typical curves of secondary circuit

Click on the pictures to download the pdf version


ModvSol Solo 1 
Basic / High Efficiency


Heat supply pump unit to load one buffer tank. Suitable for a solar collectors surface up to 70 m2.

The pump unit, as shown in the illustrative scheme at side, gets the heat from the primary circuit (solar) and brings it to the heat exchanger. Then the thermic energy is tranferred to the secondary circuit, and in the specific case of ModvSol Solo 1, the loading of the buffer tank is done in only one point, because the pump unit cannot manage the control of the stratification. 
To do the loading in stratification, use the pump unit ModvSol Solo 2.


NOTE: The schemes are incomplete and to be considered just as an indication.

 
 

(A) -
(B) -

(C) -


Solar collectors
Circulating pump of 
primary circuit
Circulating pump of secondary circuit
(D) -
(E) -

(F) -
(G) -
Heat exchanger
Mechanical flowmeter
or digital VFS sensor
Buffer tank
Temperature sensors


Solo 1 High Flow

Article code
Tapping surface
of solar collectors
Delivered
thermic power
Δt Primary circuit
circulating pump
Secondary circuit
circulating pump
Solo 1 Basic HF
031200-24-(28/40)-TD 30 m2 15 kW 10 K Wilo Star 
RSG 25/8
Wilo Star 
RS 25/6
031200-40-(38/40)-TD 46 m2 23 kW 10 K Wilo Stratos 
Para 25/1-8
Wilo Star 
RS 25/6
Solo 1 High Efficiency HF
031200-24-(28/40)-LT 30 m2 15 kW 10 K Wilo Stratos 
Para 25/1-7
Wilo Stratos 
Para 25/1-7
031200-40-(38/40)-LT 46 m2 23 kW 10 K Wilo Stratos 
Para 25/1-8
Wilo Stratos 
Para 25/1-7


Solo 1 Low Flow

Article code Tapping surface
of solar collectors
Delivered
thermic power
Δt Primary circuit
circulating pump
Secondary circuit
circulating pump
Solo 1 Basic LF
031200-24-(28/40)-TD 50 m2 25 kW 25 K Wilo Star 
RSG 25/8
Wilo Star 
RS 25/6
031200-40-(38/40)-TD 70 m2 35 kW 25 K Wilo Stratos 
Para 25/1-8
Wilo Star 
RS 25/6
Solo 1 High Efficiency LF
031200-24-(28/40)-LT 50 m2 25 kW 25 K Wilo Stratos 
Para 25/1-7
Wilo Stratos 
Para 25/1-7
031200-40-(38/40)-LT 70 m2 35 kW 25 K Wilo Stratos 
Para 25/1-8
Wilo Stratos 
Para 25/1-7
It is possible to select two versions for each model indicated in the above table: one with mechanical flowmeter, another with digital VFS sensor.

Models with mechanical flowmeter:
 the flowmeter has a measuring range of 8-28 or 8-38 l/m, default value according to the specific model selected. Product codes of these models have respectively the options 28 or 38. For instance: Solo 1 Basic HF with an exchanged power of 23 kW: code 031200-40-38-TD.

Models with digital VFS sensor:
 all these models have the VFS sensor with a measuring range of 2-40 l/min. Product code of these models have the option 40. For instance: Solo 1 Basic HF with an exchanged power of 23 kW: code 031200-40-40-TD.